LSI 3ware SAS 9750-8i Betriebsanweisung Seite 126

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 342
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 125
Configuring Units
114 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Figure 55. Read Cache policy on the Controller Settings page
After you change the selection, the page refreshes, and a message at the
top confirms the change you have made.
To change the Read Cache unit policy In 3BM
1 At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears, indicating that the RAID unit is selected.
2
Tab to the Maintain Unit button and press Enter.
3 On the pop-up menu, select
Configure and press Enter.
4 In the Configure Disk Array screen,
Tab to the field Read Cache
Setting
.
The current setting—Intelligent, Basic, or Disabled—is shown.
Seitenansicht 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 341 342

Kommentare zu diesen Handbüchern

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema