Problems and Solutions
www.lsi.com/channel/products 245
information is available at
http://www.lsi.com/channel/support/marketing_resources/index.html.
A unit shows up as unusable, because of missing drives:
Unusable Arrays:
3 drive 64K RAID 5 558.77 GB (Unit 1)
SATA - Maxtor 6B300S0 279.86 GB (Port 6)
The unit has some but not all of its members available.
The unit will be unusable. If this unit is your boot
device, your system will not boot. You must either
return the missing disks to complete the unit, or
release the member disks by deleting the incomplete
unit(s) listed in the display. Remember that deleting
a RAID unit overwrites any existing data on the member
drives.
CAUTION:
Do not delete the inoperable unit and recreate it, as this will
overwrite the data and make data recovery very difficult.
If you get this error, contact technical support at
http://www.lsi.com/channel/ContactUs.
Problems in 3DM and 3BM
A 3ware RAID controller does not show in the list of controllers
You may not have the most recent driver for your controller, the driver may
not be loaded, or you may not have the most recent version of the CLI or
3DM.
To find out the driver version currently installed, see “Determining the
Current Version of Your 3ware Driver” on page 176
Current drivers and software are available for download on the LSI website at
http://www.lsi.com/channel/ChannelDownloads.
When booting a system, a drive is not showing up in the startup
screens, in 3BM, or in 3DM
This could be due to one or more of the following:
• Defective cable
• Defective drive
• Defective enclosure or drive slot
• Poorly seated drive
• Poorly connected power cable
• Poorly connected data cable