Troubleshooting
258 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
“Basic Troubleshooting: Check This First” on page 239
000F SMART threshold exceeded
Event Type
Warning
Cause
SMART monitoring is predicting a potential drive failure.
The 3ware RAID controller supports SMART monitoring for SATA and SAS
drives, whereby the individual drives automatically monitor certain
parametric information such as error rates and retry counts. This type of
monitoring may be able to predict a drive failure before it happens, allowing
you to schedule service of the unit before it becomes degraded. The SMART
status of each drive attached to the 3ware RAID controller is monitored daily.
Action
LSI recommends that you replace any drive that has exceeded the SMART
threshold.
If the drive is part of a redundant unit, remove the drive through 3DM 2 or
CLI. Replace the drive and start a rebuild.
If the drive is not part of a redundant unit, then you will need to backup your
data before replacing the drive.
See Also
“Viewing SMART Data About a Drive” on page 150
“Rebuilding Units” on page 160
0019 Drive removed
Event Type
Warning
Cause
A drive was physically removed from the controller while the controller was
powered on.