Error and Notification Messages
www.lsi.com/channel/products 269
See Also
“About Initialization” on page 152
0030 Drive not supported
Event Type
Error
Cause
3ware 8000 and 9500S Serial ATA controllers only support UltraDMA-100/
133 drives when using the parallel-to-serial ATA converter. This message
indicates that an unsupported drive was detected during rollcall or a hot swap.
This message could also indicate that the parallel-to-serial converter was
jumpered incorrectly.
Action
Use a parallel ATA drive which supports UDMA 100 or 133 and check that
the parallel-to-serial converter was correctly jumpered to correspond to
UDMA 100 or 133 drives.
See Also
For a list of compatible drives, see the Interoperability list on
http://www.lsi.com/channel/support/marketing_resources, through the Data &
Interoperability tab.
0032 Spare capacity too small
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.