Seitenansicht 303
Troubleshooting
292 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
The enclosure temperature is lower than normal.
Action
In general, cooler operating temperatures are good for enclosure components.
However, if the temperature is very cold, condensation can occur and cause
media errors and damage. Take steps to bring the operating environment back
within the enclosure manufacturers specifications.
Allow cold equipment to warm up gradually before powering on.
8022 Enclosure temp high
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
The enclosure temperature is higher than normal.
Action
Take steps to lower the enclosure temperature, such as adding fans, clearing
enclosure openings of blockages, and increased ventilation.
Make sure that the enclosure environment does not get any hotter. See your
enclosure documentation or contact your enclosure manufacturer to ensure
that you are adhering to proper operating conditions and environments.
8023 Enclosure temp below operating
Event Type
Information.
Cause
Applies to 9750 and 9690SA controllers.
The enclosure temperature is below the enclosure manufacturers specified
operating temperature.
Action
In general, cooler operating temperatures are good for enclosure components.
Seitenansicht 303
1 2 ... 299 300 301 302 303 304 305 306 307 308 309 ... 341 342

Kommentare zu diesen Handbüchern

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema