Setting Unit Policies
www.lsi.com/channel/products 121
The current setting—Protection, Balanced, or Performance—is shown.
(The default setting is Balanced.)
5 Press
Enter to display the choices, use the arrow keys to select the
setting you want, and press
Enter again to choose it.
6
Tab to the OK button and press Enter to select it.
You return to the main 3BM screen.
7 When you are finished making changes, press
F8 to save them and exit
3BM.
Rapid RAID Recovery
The Rapid Raid Recovery feature increases the speed with which a redundant
unit can be made redundant again when a rebuild is required. It can also
increase the speed of verification or initialization that may occur in the event
of an unclean shutdown.
Rapid RAID Recovery is possible because the firmware maps the unit, and
tracks the areas of the unit where write activity occurs. Then, if a rebuild,
initialization, or verify is required, the controller only has to address the active
areas. The fewer active areas, the faster the rebuild, initialize or verify.
Since the units are mapped out and tracked from the creation of the unit, this
feature can only be enabled during unit creation. Also, once disabled, it
cannot be re-enabled.
The more space is available on a unit, the more benefit you will see in the
event of a rebuild, if you enable Rapid RAID Recovery. If all of a unit’s
capacity is being used, you may not see reduction of rebuild speed when using
Rapid RAID Recovery. However, Rapid RAID Recovery still provides
benefits to unit verification and to initialization after an unclean shutdown,
regardless of the disk usage.
Possible settings are
All (labeled Fast Rebuild/Shutdown in 3BM), Rebuild or
Disable. All will apply the policy to both rebuilds and unclean shutdowns.
Rebuild will apply only to rebuilds. Disable means that rebuilds,
initializations and verifies will take place on the entire unit, not just the active
sections. The default setting is
All.
There is some system overhead from setting rapid recovery to
All. If you have
a BBU, you can set rapid recovery to
Rebuild, as a BBU provides protection
against data loss in the event of an unclean shutdown.
Some limitations of Rapid RAID Recovery:
Seitenansicht 132
1 2 ... 128 129 130 131 132 133 134 135 136 137 138 ... 341 342

Kommentare zu diesen Handbüchern

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema