Checking Unit and Drive Status through 3DM
www.lsi.com/channel/products 143
Unit Statuses
The following is a list of unit statuses you may see in 3DM 2:
OK. The unit is optimal and is functioning normally.
Rebuilding. The unit is in the process of writing data to a newly added
disk in a redundant unit, in order to restore the unit to an optimal state.
The unit is not fully fault tolerant until the rebuilding is complete. For
more information, see “To verify a unit through 3BM” on page 159.
Rebuild-Paused. The unit is set to rebuild, however scheduling is
enabled, and the present time is not during a scheduled timeslot.
Rebuilding will start at the next scheduled time slot. Rebuilds are also
paused for up to ten minutes after a reboot, even during a scheduled
timeslot.
Initializing. The unit is in the process of writing to all of the disks in the
unit in order to make the array fault tolerant. For more information, see
“About Initialization” on page 152.
Initializing-Paused. The unit is set to initialize, however scheduling is
enabled and the present time is not during a scheduled timeslot.
Initializing will start at the next scheduled time slot. Initializations follow
the Rebuild/Migrate task schedule. Initialization is also paused for up to
ten minutes after a reboot, even during a scheduled timeslot.
Verifying. The unit is in the process of ensuring that the parity data of a
redundant unit is valid. For more information, see “About Verification”
on page 155.
Verify-Paused. The unit is set to verify, however, scheduling is enabled,
and the present time is not during a scheduled timeslot. Verification will
start at the next scheduled time slot.
Migrating. The unit is in the process of being reconfigured while it is
online. Migration can be used to change the RAID level, to expand the
capacity by adding additional drives, or to change the stripe size. For
more information, see “Changing An Existing Configuration by
Migrating” on page 123.
Solid red Drive fault
This drive has failed. You should replace it and rebuild the unit.
Blinking red Predicted drive fault
3ware software predicts that this drive will fail soon. You may
want to replace it.
Table 11: Meaning of LED Colors and Behavior
Color Drive Status
Seitenansicht 154
1 2 ... 150 151 152 153 154 155 156 157 158 159 160 ... 341 342

Kommentare zu diesen Handbüchern

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema